Setup and Functioning
10
/
58
20.03.2015
8LE-D23_BA_E
3.1. Setup and Functioning
LED flood light for steady and pulsed operation.
Pulsed operation is synchronized with the high-speed camera. In pulsed operation, 80% more
lighting power can be output compared to steady operation. This is possible because the lighting is
only switched on when the camera requires light. The M=Light-LED can optionally be operated
manually or via the CAN-bus with the help of the software. In pulsed operation it is possible to
eliminate backlight effects due to control of separate M=Light-LED groups. For elimination of
backlight effects, only one camera synchronized with one M=Light-LED group is switched on
(Figure 1).
Figure 1: Synchronization in pulsed operation
Item:
Description
1
Camera 1 switched on
2
M=Light LED group 1 switched on
3
M=Light LED group 2 switched off
4
Camera 2 switched off
5
Camera 1 switched off
6
M=Light LED group 1 switched off
7
M=Light LED group 2 switched on
8
Camera 2 switched on