37
Parameter
Description
Settings
.7) Photocell active - Safety edge active.
Open completely if mains power is present.
If mains power is not present, stop and then close again after
the configured time (parameter 0.6).
0.6 Delay activation of
safety edge protection
in case of fire
0 – 60 Seconds
3 sec.
0.7 Safety edge function
within range pre-end
switch
.1) Stop if safety edge is operated
X
.2) Deactivate/ignore safety edge
0.8 Return time after
safety edge activation
.0) Fast
X
.1)
.2)
.3) Slow
0.9 Type End switch .0) Automatic
X
.1) DES 3.2 GFA (new protocol)
.2) DES GFA (old protocol)
.3) DES Kostal
.4) NES