42
Parameter
Description
Settings
configured position.
4.5 Delay time response to
start emergency/accident
alarm.
0 to 10 minutes.
0 min.
4.6 Choice reset in case of fire
alarm
.1) No reset needed.
X
.2) Reset needed for fire alarm input 1.
.3) Reset needed for fire alarm input 2.
.4) Reset needed for fire alarm input 1 and 2.
4.7 Delay time door release
after reset.
0 to 240 seconds.
60 sec.
4.8 Activating half open in case
of alarm/emergency.
(Must only be set for DES,
Par. 4.9)
.1) Deactivated;
door opens fully when escaping during a fire.
X
.2) Activated;
when escaping during a fire, the door opens to the
position configured in parameter 4.9.
4.9 Position half open in case
of alarm/emergency.
Use the buttons on the circuit board to open the door
to the desired end position.
Press OK button to confirm or press stop button on lid
to cancel.