EasyManua.ls Logo

Metacon-Next FirePro V4 - Page 44

Metacon-Next FirePro V4
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
Parameter
Description
Settings
2.5) Obstacle detection; activated if the photocell and/or safety
edge input is interrupted/activated for a configured time
(parameter 5.4).
5.3 Choice after
deactivation fire
alarm(s)
(Terminals X 16
)
.1) Door closes until an open button, sensor input or stop button is
operated.
X
.2) Door stops immediately.
5.4
Time
obstacle
detection
1 to 60 minutes.
1
min.
5.5 Function
LED/buzzer signal
transmitter.
.1)
For all error messages and fire alarm/emergencies.
Only activate again after longer than 30 seconds for photocell
and/or safety edge.
X
.2) For all error messages and emergencies.
.3) Only for fire alarm/emergency.
.4) Off.
5.7 Type fire alarm
input 2
.1) 8.2kΩ resistor.
X
.2) Potential-free NC contact.
5.8 Reverse direction
of rotation (motor
with NES)
.1) Retain direction of rotation.
X
.2) Reverse direction of rotation.
5.9 Pass door/slack
cable
.1) 5,1kΩ resistor
X
.2) Potential-free NC contact.