Do you have a question about the Metrohm NIRS DS2500 and is the answer not in the manual?
Analysis Type | NIR spectroscopy |
---|---|
Wavelength Range | 400 - 2500 nm |
Spectral Resolution (700 nm) | 2 nm |
Spectral Resolution (2100 nm) | 10 nm |
Connectivity | USB, Ethernet |
Light Source | Tungsten Halogen Lamp |
Protection | IP54 |
Sample Type | Liquids, solids, powders, pastes |
Interface | Touchscreen |
Detector | InGaAs |
Detector Type | PbS |
Detailed explanation of the NIRS DS2500 Analyzer's design and functionality.
Outlines the primary applications and usage scenarios for the NIRS DS2500 Analyzer.
Information regarding the manual's content, structure, and conventions.
Explains symbols, formatting, and warnings used throughout the documentation.
Provides essential safety guidelines for operating and maintaining the NIRS DS2500 Analyzer.
General safety precautions applicable to the operation of the NIRS DS2500 Analyzer.
Specific safety information related to the electrical aspects of the NIRS DS2500 Analyzer.
Safety measures when working with flammable materials alongside the instrument.
Guidelines for the proper recycling and disposal of the NIRS DS2500 Analyzer.
Identifies and describes components located on the front panel of the NIRS DS2500 Analyzer.
Identifies and describes components located on the rear panel of the NIRS DS2500 Analyzer.
Step-by-step guide for unpacking and verifying the instrument upon arrival.
Instructions for handling and storing the instrument's protective packaging.
Procedures for checking the instrument shipment for completeness and damage.
Details the intended environments (lab or atline) for using the NIRS DS2500 Analyzer.
Guidelines and conditions for properly setting up the NIRS DS2500 Analyzer.
Specifies the environmental conditions necessary for optimal instrument performance.
Outlines general environmental requirements, including dust and dirt prevention.
Advises on avoiding vibrations and shocks to maintain instrument accuracy.
Detailed instructions for connecting the NIRS DS2500 Analyzer to a power source.
Procedures for connecting the instrument to a computer via a data cable.
Steps involved in powering on the NIRS DS2500 Analyzer.
Guide for the first-time operational setup and calibration of the instrument.
Instructions for installing and using various accessories with the NIRS DS2500 Analyzer.
Procedure for inserting sample cups for granulated materials.
Procedure for inserting sample cups for powder samples.
Procedure for inserting sample cups for liquid samples.
Information on professional maintenance services provided by Metrohm.
Tasks and intervals for routine maintenance performed by the user.
Step-by-step guide for replacing the lamp in the NIRS DS2500 Analyzer.
Instructions on how to check, clean, or replace the fan filter.
Procedure for safely replacing the fuses in the NIRS DS2500 Analyzer.
Common problems encountered during initial instrument startup and their solutions.
Explains software error codes and provides remedies for troubleshooting.
Details the communication interfaces available on the NIRS DS2500 Analyzer.
Specifies the electrical power requirements and fuse details for the instrument.
Lists the recommended temperature and humidity ranges for operation and storage.
Provides key operational parameters such as measuring mode and wavelength range.
Outlines the safety standards and directives the instrument complies with.
Lists relevant industry standards and EU directives followed by the instrument.
Provides the physical dimensions and weight of the NIRS DS2500 Analyzer.