METTLER TOLEDO 2888 Deckmate Floor Scales Installation and Service Manual
(10/96)
3-4
Reinstall Platform
Clear all debris from the scale area. Ensure that all four load pin
receivers in the frame are clean and free of all foreign material.
Replace the platform into the frame. Make sure there is slack in the
cable between the frame and platform and that no cable pinching occurs.
Oscillate the platform to ensure that the rocker load pins are seated in the
receivers and no binding exists.
Calibrate the scale per the Mettler Toledo Indicator Manual.
Mode of Operation
The model 2888 uses an analog junction box for summing the load cell
outputs. Only analog compatible indicators will work with the model
2888. The correct cable connection can be seen in Figure 3-c.