Operational Shocks 7.2 Equipment Category B
Crash Safety 7.3 Equipment Category B Type 5
Vibration 8.0 Aircraft zone 2; type 3, 4, 5 to
category S level M, type 1
(Helicopters) to category U level G
Explosion 9.0 Equipment identified as Category X
– no test required
Waterproofness 10.0 Equipment identified as Category X
– no test required
Fluids Susceptibility 11.0 Equipment identified as Category X
– no test required
Sand and Dust 12.0 Equipment identified as Category X
– no test required
Fungus 13.0 Equipment identified as Category X
– no test required
Salt Spray 14.0 Equipment identified as Category X
– no test required
Magnetic Effect 15.0 Equipment tested to Category Z,
safe distance 20cm
Power Input 16.0 Equipment Category BXX
Voltage Spike 17.0 Equipment Category B
Audio frequency
conducted
susceptibility
18.0 Equipment Category B
Induced signal
susceptibility
19.0 Equipment Category AC
Radio frequency
susceptibility
20.0 Equipment Category TT
Radio frequency
emission
21.0 Equipment Category B
Lightning induced
transient susceptibility
22.0 Equipment identified as Category
B2G2L2 – no test required
Lightning direct
effects
23.0 Equipment identified as Category X
– no test required