The V
DD
sense connection draws very little current from the target processor. The actual power comes from the
MPLAB PICkit 4 In-Circuit Debugger system, as the V
DD
sense line is used as a reference only to track the target
voltage.
The clock and data connections are interfaces with the following characteristics:
Clock and data signals are in high-impedance mode (even when no power is applied to the MPLAB PICkit 4 In-
Circuit Debugger system).
Clock and data signals are protected from high voltages caused by faulty target systems, or improper
connections.
Clock and data signals are protected from high current caused from electrical shorts in faulty target systems.
Table 11-4. Electrical Logic Table
Logic Inputs V
IH
= V
DD
x 0.7V (min.)
V
IL
= V
DD
x 0.3V (max.)
Logic Outputs V
DD
= 5V V
DD
= 3V V
DD
= 2.3V V
DD
= 1.4V
V
OH
= 3.8V min. V
OH
= 2.4V min. V
OH
= 1.9V min. V
OH
= 1.0V min.
V
OL
= 0.55V max. V
OL
= 0.55V max. V
OL
= 0.3V max. V
OL
= 0.1V max.