21
Hello Time (1-10):
The scale of 1 ~ 10 sec will be set as a period of time that
how often the switch broadcasts hello messages to other switches.
Max Age (6-40):
The number of seconds (from 6 ~ 40) which determines the
amount of time that protocol information received on a port is stored by the
switch.
Forward Delay Time (4-30):
The number of seconds (from 4 ~ 30) which
determines how long each of the listening and learning states will last before
the port begins forwarding.
Force version:
Select the RSTP default protocol. Normal means RSTP
protocol. Compatiblemeans it’s compatible with STP protocol.
RSTP Configuration interface