MICROSENS 8 Port Gigabit Ethernet Switch User’s Manual
159
set sms
Syntax:
set sms <range>
Description:
To enable the sms of the events.
Argument:
<range>:set the range of sms, syntax 1,5-7
Possible value:
<range>: 1~24
Example:
MICROSENS(alarm-events)# set sms 1-3
set trap
Syntax:
set trap <range>
Description:
To enable the trap of the events.
Argument:
<range>:set the range of trap, syntax 1,5-7
Possible value:
<range>: 1~24
Example:
MICROSENS(alarm-events)# set trap 1-3
show
Syntax:
show
Description:
To display the configuration of alarm event.
Argument:
None.
Possible value:
None.