MICROSENS 8 Port Gigabit Ethernet Switch User’s Manual
192
max-pkt-len
set len
Syntax:
set len <range> <length>
Description:
To set up the maximum length of the packet that each port of the switch can accept. Argument:
<range>: port range, syntax 1,5-7, available from 1 to 8
<length (bytes)>: maximum packet length
Possible value:
<range> : 1 to 8
<length (bytes)>: 1518/1532/9208
Example:
MICROSENS(max-pkt-len)# set len 1-8 9208
show
Syntax:
show
Description:
To show current setting of maximum packet length setting.
Argument:
None.
Possible value:
None.
Example:
MICROSENS(max-pkt-len)# show
PORT Max Packet Length
------ -------------------
1 1532
2 1532
3 1532
4 1532
5 1532
6 1532
7 1532
8 1532

Table of Contents