Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)
1. Fluorinated greenhouse gases are contained in hermetically sealed equipment. For
specific information on the type, the amount and the CO2 equivalent in tonnes of
the fluorinated greenhouse gas(on some models), please refer to the relevant label
on the unit itself.
Installation, service, maintenance and repair of this unit must be performed by a
certified technician.
Product uninstallation and recycling must be performed by a certified technician.
2.
3.
UV-C lamp(Applicable to the unit contains an UV-C lamp only)
This appliance contains an UV emitter. Do not stare at the light source.
This appliance contains a UV-C lamp. Read the maintenance instructions before
opening the appliance.
1. Do not operate UV-C lamps outside of the appliance.
2. Appliances that are obviously damaged must not be operated.
3. Unintended use of the appliance or damage to the housing may result in the
escape of dangerous UV-C radiation. UV-C radiation may, even in small doses,
cause harm to the eyes and skin.
4. Before opening doors and access panels bearing the ULTRAVIOLET RADIATION
hazard symbol for the conducting USER MAINTENANCE, it is recommended to
disconnect the power.
5. The UV-C lamp can not be cleaned, repaired and replaced.
6. UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not
be removed.
WARNING
WARNING for Using R32/R290 Refrigerant
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open flames, an operating gas appliance or an operating
electric heater).
Do not pierce or burn.
Be aware that the refrigerants may not contain an odour.
Appliance should be installed, operated and stored in a room with a floor area
according to the amount of refrigerant to be charged. For specific information on
the type of gas and the amount, please refer to the relevant label on the unit itself.
Appliance should be installed, operated and stored in a room with a floor area
larger than 4 m.
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
The appliance shall be stored so as to prevent mechanical damage from occurring.
A warning that the appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment
authority, which authorises their competence to handle refrigerants safely in
accordance with an industry recognised assessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of flammable
refrigerants.
The appliance shall be stored in a room without continuously operating open flames
(for example an operating gas appliance) and ignition sources (for example an
operating electric heater).