Special Function Description
Protect Function Description
Heating time limit protection:
● If the boiling Starting working time is more than or equal to 16 (± 1) minutes, if
the boiling Starting function is started, the kettle will automatically enter the
dechlorination working state; if the boiling water heat preservation function is
started, the buzzer will sound three times, and the kettle will automatically enter
into the heat preservation working state.
Sensor abnormal protection:
● During the boiling process, the water temperature in the kettle is less than or
equal to 80 , the temperature does not rise by 1 within 5 minutes (± 20s),
the heating tube stops heating, and the alarm is given at the same time.
The nixie tube displays E7 and the buzzer sounds 10 times to enter the failure
mode.
Sensor over temperature protection:
● Continuously detect that the temperature of the temperature sensor in the
kettle is greater than or equal to 120 for 1s, and the heating pipe stops heating
and alarms at the same time.
The nixie tube displays C1 and the buzzer sounds 10 times to enter the failure
mode.
Sensor short circuit protection:
● If the temperature sensor in the pot is short circuited for 0.5s continuously, the
heating tube stops heating and alarms at the same time.
The nixie tube displays E2, and the buzzer beeps all the time and enters the
failure mode.
Sensor open circuit protection:
●The open circuit of the temperature sensor in the pot is detected for 0.5s
continuously, and the heating pipe stops heating, and the alarm is given at the
same time.
●The nixie tube displays E1 and the buzzer sounds 10 times to enter the failure
mode.
Zero crossing abnormal protection:
● If abnormal zero crossing signal is detected for 5S, the heating pipe will stop
heating and alarm at the same time.
The nixie tube displays E0 and the buzzer sounds 10 times to enter the failure
mode.
11
● If it is detected that the current temperature suddenly drops below - 8 of the
insulation temperature during the working process, it is considered that cold
water has been added midway.
● if cold water is detected during gap heating, the program adjusts the heating
ratio appropriately according to the difference