V6R VRF 50/60Hz
115
Part 6 - Diagnosis and Troubleshooting
Step 8: Vacuum drying and refrigerant charging
Once all the compressors and other components have been fully connected, vacuum dry the system and recharge
refrigerant.RefertotheV6REngineeringDataBook,Part3.
Figure 6-2.10: Inspecting compressor oil


Thisoilisblack
-ithasbeen
carbonized
Thisoilisalittle
yellow,butisclear
andtransparentand
theconditionis
acceptable
Thisoilisstill
transparentbutthere
areimpuritieswhich
mayclogthefilter
Cloudyorgray
oilindicates
abnormal
system
operation
Thisoilcontains
particlesofcopper