1 Remove the air duct components in freezing
chamber.
2 Disconnect all connectors.
3 Remove the welding on inlet and outlet tubes.
4 Remove two screws which are used to fix the
evaporator and remove the evaporator.
Components on the evaporator
Fuse
The fuse is located on top of the evaporator
1 connect the fuse connector.
2 Cut off the band which fixes the fuse.
3 Separate the fuse and the evaporator.
*,Don’t break the welding of the evaporator in case that
only the fuse needs to be replaced.
Defrost sensor
The defrost sensor is located on top of the evaporator.
1 Disconnect the connector of defrost sensor
2 Cut off the band which fixes the sensor.
3 Separate the sensor and the evaporator.
*,Don’t break the welding of the evaporator in case that
only the sensor needs to be replaced.
Defrost heater
The defrost heater is located at bottom of the evaporator.
1 Disconnect the connector of defrost heater.
2 Cut off the band which fixes the defrost heater.
3 Take off the defrost heater from the evaporator.
*,Don’t break the welding of the evaporator in case that
only the defrost heater needs to be replaced.
Ambient temperature sensor