11
Chapter 2 - Specification
Machine Weights
SL6 SL10 SL12
Lbs. 7000 7000 13,250
Kg 2700 2700 6000
Current/Voltage requirements
SL6 SL10 SL12 STD SL12 OPT
Voltage 208-240 VAC 208-240 VAC 208-240 VAC 208-240 VAC
Current 50 Amps 60 Amps 60 Amps 100 Amps
Transformer 11 KVA 20 KVA 20 KVA 38 KVA
Coolant Capacities
SL6 SL10 SL12
Gallons 36 36 48
Liters 140 140 185
Coolant Recommendation
Consult with a reputable coolant supplier in your area. You should use non-toxic, non-
corrosive, and non-flammable coolant. Avoid chlorine and sulfur, which may harm the
paint finish.
Hydraulic Fluid Tank Capacity
Use Mobil DTE24 or Equivalent
SL6 SL10 SL12
Gallons 10.5 10.5 18
Liters 40 40 68
Control Instructions, Schematics, Complete Specification Sheets
• Detailed instructions for programming the machine and operating it from the front
panel are given in the CNC operation manual provided separately.
• Electrical schematics, pneumatic diagrams (if applicable) and hydraulic diagrams
(if applicable) are located in the electrical and mechanical manual.
Machine specification sheets including travels, tool capacity, etc. are included at the back
of this manual.