CHAPTER 3 – SITE PREPARATION
Air Supply System (if equipped)
Some Milltronics turning centers require a constant supply of quality air pressure in
order to perform optimally. 90-110 PSI at 10 CFM is required.
Adjustments
Set the main air regulator to 90 PSI.
21
Main air pressure
gauge. Adjust
using knob “A”.
to 90 PSI
Air pressure
switch adjusted
to trip at 75 PSI.
Weekly fill with
Marvel No.085,
Mobil Velocite No.
10 or equivalent.
Water trap is self-
draining. No need
to drain manually.