Air System Maintenance (if equipped)
Ensure the air lubrication unit dispenses oil, and that the oil reservoir fill level is
maintained. (Use Marvel No. 085, Mobil Velocite No. 10 or equivalent oil, further
details about lubrication type can be found in the mechanical manual)
Ensure the automatic water trap drain is working.
Adjustments
Set the air regulator to 90 PSI.
Air pressure
switch adjusted
to trip at 75 PSI.
Main air pressure
gauge. Adjust
using knob “A”.
to 90 PSI
Weekly fill with
Marvel No.085,
Mobil Velocite No.
10 or equivalent.
Water trap is self-
draining. No need
to drain manually.