If a motor on your machine does not have grease fittings, no grease maintenance is necessary. If a
motor on your machine has grease fittings, it is necessary to add grease. But the interval is usually
longer than for other maintenance. Table 9: Motor Grease Intervals and Quantities, page 21 gives
motor grease intervals and quantities for motors with specified frame sizes and speeds. You get
this data from the motor nameplate. Use Table 5: Motor Grease Schedule, page 15 to record the
data for the motors on your machine.
CAUTION: Failure to remove grease drain plugs can cause grease to enter the
windings and burn out the motor.
If the motor has grease drain plugs, remove them before you add
grease. If the motor has grease relief fittings, it is not necessary to remove
them.