© 2011 MIMAKI ENGINEERING CO.,LTD. 6.4.8 P.1
1
2
3
4
5
6
7
8
6.4.8 X-axis Motor Relay PCB Assy
Work procedures
1. Remove the ICU Cover R.
2. Disconnect all FFCs and connectors from PCB.
3. Remove the screws and then remove the X-axis motor relay
PCB assy.
4. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF.
It is very dangerous if sleep mode functions mistakenly during the operation.
X-axis Motor Relay PCB Assy
Screw
X-axis Motor Relay PCB Assy
R.1.0