© 2011 MIMAKI ENGINEERING CO.,LTD. 6.4.11 P.1
1
2
3
4
5
6
7
8
6.4.11 Slider PCB Assy
Work procedures
1. Remove the following covers.
• Front cover
• Y Cover F
• Y Cover R
2. Move the ink carriage onto the station and disconnect all cables
from PCB.
3. Remove the screws and then remove the slider PCB assy.
4. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15 minutes
before restarting the operation. It is very dangerous if sleep mode functions mistakenly during the
operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pressure
part of the power supply PCB assy. Take care to avoid contact with it.
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > Slider PCB Assy
Model
TS34-1800A
Issued
2011.10.17
Revised F/W ver
1.20
Remark
1.0