2. Maintenance Methods
11
4
Clean the cap rubber.
Wipe off any ink and dust adhering using a cleaning stick moistened with maintenance liquid. Wipe
off the maintenance liquid. Make sure none remains.
Cap rubber
5
Check to confirm that the cap slider is not tilted once cleaning is complete.
If the cap slider is tilted, move the slider block to the left or right to correct the tilt.
6
Close the front cover, then press the [ENTER] key.
NCU Cleaning
The NCU uses a sensor to monitor the ink droplets ejected from the print head nozzles. Continuing to use
the dirty NCU may prevent the nozzle check function from operating correctly.
Be careful to avoid leaving fragments from the cleaning stick behind when cleaning. These
fragments will increase the risk of ejection failures (e.g., nozzle clogging or deflection).
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Platen Right End], then press the [ENTER] key.
The carriage moves over the platen.
3
Open the front cover.