3. Consumable Item Replacement
24
LED Glass Replacement
Replace with new LED glass if the ink hardens and the existing LED glass becomes dirty.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Maint. Space], then press the [ENTER] key.
The carriage moves to the maintenance space.
3
Open the maintenance covers.
4
Remove the LED glass.
Unclip the tabs and slide the LED glass in the direction of the arrow to remove.
Be careful not to apply too much force when unclipping the tabs. Disregarding this precaution may
result in breakage of the tabs.
Claw
5
Mount new LED glass.
Insert until it clicks into place. Confirm that the tabs are engaged.
6
Once replacement is complete, close the cover, then press the [ENTER] key.