32
WARNING MESSAGES
MESSAGE DESCRIPTION
LOW BATT VOLTAGE Appears at power-up if the battery voltage is below 3.6 Volts.
Change batteries.
MASTER MISSING! Attempted to read data from the MASTER AND
CONFIGURATION PORT without a Master or Configuration EPM
installed.
MASTER SHORTED! The EPM in the MASTER AND CONFIGURATION PORT is
damaged or installed incorrectly.
NAME EXISTS!!! Attempted to copy data from the computer file buffer and a file
was not downloaded from the computer.
NO COMPUTER FILE Attempted to copy data from the computer file buffer and a file
was not downloaded from the computer.
NOT ENOUGH SPACE There is not enough memory to store another data file.
NO VALID FILES Attempted COMPUTER TO EPM function and the EPM
Programmer could not establish communications with the
computer.
PROGRAMR OFFLINE Attempted COMPUTER TO EPM function and the EPM
Programmer could not establish communications with the
computer.
READ ONLY FILE! An attempt was made to edit or delete the DEFAULTS data file.
SERIAL TIMEOUT! The EPM Programmer was requesting data from a computer and
a response was not received within 5 seconds.
TRANSFER FAILED The EPM Programmer could not properly transfer data to the
target EPM. This may indicate a problem with the EPM
Programmer or the target EPM.

Other manuals for Minarik AC200 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minarik AC200 SERIES and is the answer not in the manual?

Minarik AC200 SERIES Specifications

General IconGeneral
BrandMinarik
ModelAC200 SERIES
CategoryController
LanguageEnglish

Related product manuals