26
3. Once the desired data file is found, press ENTER. The display will ask for confirmation to
delete the file.
4. Press ENTER to confirm that the file be deleted. The display will read DELETING and
then FILE DELETED!!! when finished erasing the file.
5.2.7 LOAD CNFG EEPROM
This function is used to load parameter configurations into the EPM Programmer so that it can
be used to edit stored data files with different parameter versions. The parameter version of
the drive will change as the product is upgraded in performance and/or functionality. Once a
drive is manufactured, its parameter version cannot be changed, and the EPM installed in the
drive must have the same parameter version, or the drive will not operate.
Likewise, the configuration version of the EPM Programmer must match the parameter version
of a data file in order to edit that data file. The EPM Programmer can store data files with
different parameter versions, but can only edit files which match the configuration version.
This feature allows one EPM Programmer to be used with past, present, and future parameter
versions.
NOTE: This feature requires special Configuration EPMs. Please consult this factory.
Follow the procedure below to load a new configuration:
1. Install the configuration EPM into the MASTER AND CONFIGURATION PORT.
2. Use the MENU key to scroll to LOAD CNFG EEPROM.