20
21
The Lithium Ion battery is specifically designed
for the GPX-4500.
The Lithium Ion battery is not compatible with
non GPX detectors. The GPX-4500 is supplied with a
power lead which has been specifically designed to fit
GPX detectors only. Attempting to use the Lithium Ion battery
pack with other detectors may damage the detector or the battery pack.
Do not try to adapt this battery to other models as it will very likely
cause damage.
Do not charge the battery at temperatures above 45°C (11F).
Do not charge the battery at temperatures below 0°C (32°F).
Do not leave the battery in hot conditions (e.g. on the dashboard
of your car or rear parcel shelf).
Do not immerse the battery in any liquid or allow water ingress.
Do not throw the battery or impact it in any way.
Do not short-circuit the battery.
Do not use the battery if it is damaged or deformed.
Do not disassemble or reconstruct the battery.
Do not incinerate the battery.
In the event of a fault, you should return the battery to a Minelab
authorised service centre for repair.
The use of non-approved components will VOID YOUR WARRANTY.
There are no user serviceable parts within this battery pack.
Battery LED Patterns
Brief cycling red-orange-green: Occurs when the charger is turned on or when
a new battery is connected
Solid orange: First phase of charge
Orange with green blink: Last phase of charge
Solid green: Battery is charged
Slow red blinking: The battery is too hot. It has reached a
temperature over 50°C (122°F) and will not
charge. Disconnect the battery and wait for
it to cool below 40°C (104°F) in a cool place
before reconnecting.
Continuous orange blinking: The first phase of charging has timed out. If
this continues to occur each time the battery
is charged the battery is no longer functioning
correctly. Contact your dealer.
Solid red: There is a fault with the battery.
Disconnect and reconnect the battery.
If the LED is still red contact your dealer.
Routine
Exceptions
Taking Care
of Your Battery

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minelab GPX-4500 and is the answer not in the manual?

Minelab GPX-4500 Specifications

General IconGeneral
Search ModesGeneral, Deep, Custom
Battery LifeUp to 12 hours
Ground BalanceAutomatic and Manual
DisplayLCD
TechnologyMPS, DVT, SETA
Coil11" Double-D Coil
Audio OutputInternal speaker, headphone jack
BatteryLithium-ion
WaterproofCoil is waterproof
Warranty3 years