MBE059F03
32 / 32
29. Appendix B -- Parameter
Parameter Display Description Default Remarks
0
CHAnGE
Load datum value 0
1
dir
Select counting direction (+ / -) -dir
2
OriGin
Load origin 0.00mm
3
OffS-
Set tool diameter 0.00mm
4
POSdir
Positioning mode ┤├─
5
SPEEd
One or two speed positioning 1sp
6
rEtr
Retract distance 5.00mm
7
diA
Conveyer diameter 50.00mm
8
PPr
Pulse/rev input from conveyer 4
9
LOAd 0
Load tool diameter 0.00
10
Lo-End
- Software limit -50.00mm
11
Hi-End
+ Software limit 1000.00mm
17
tOLL
Tolerance 0.30mm
18
StEP
Fine adjustment distance 1.00mm
19
FAuLt
Low speed limit 55
20
LinCOr
Linear correction 1.00000
30
PASS
Parameter lock ----
33
SOurCE
Software version
55
PrOG-
Fast program
90
rES
Resolution 0.01mm
99
GO....
Sensor calibration No default Value