- 43 -
Form: MM-
A
4/A5SC Revised 07/13/16
Lubricator (003843-00001)
Warning: DO NOT place plastic bowl unit in service without metal bowl guard installed.
Plastic bowl units are sold only with metal bowl guards. To minimize the danger of flying fragments in the event of plastic
bowl failure, the metal bowl guards should not be removed. If the unit is in service without the metal bowl guard installed,
manufacturer’s warranties are void, and the manufacturer assumes no responsibility for any resulting loss.
If unit has been in service and does not have a metal bowl guard,
order one and install before placing back in service.
CAUTION:
Certain compressor oils, chemicals, household cleaners, solvents, paints and fumes will attack plastic bowls and can
cause bowl failure. Do not use near these materials. When bowl becomes dirty replace bowl or wipe only with a clean, dry
cloth. Reinstall metal bowl guard or buy and install a metal bowl guard. Immediately replace any crazed, cracked,
damaged or deteriorated plastic bowl with a metal bowl or a new plastic bowl and a metal bowl guard.
WE CANNOT POSSIBLY LIST ALL HARMFUL SUBSTANCES. CHECK WITH A MOBAY CHEMICAL OR GENERAL
ELECTRIC OFFICE FOR FURTHER INFORMATION ON POLYCARBONATE PLASTIC.
Except as otherwise specified by the manufacturer, this product is specifically designed for compressed air service, and
used with any other fluid (liquid or gas) is a misapplication. For example, use with or injection of certain hazardous liquids
or gases in the system (such as alcohol or liquid petroleum gas) could be harmful to the unit or result in a combustible
condition or hazardous external leakage. Manufacturers warranties are void in the event of misapplication, and
manufacturer assumes no responsibility for any resulting loss. Before using with fluids other than air, or for non-industrial
applications, or for life support systems consult manufacturer for written approval.
INSTALLATION
1. Refer to warning above.
2. Install as close as possible to the equipment requiring lubrication.
3. Install the unit with the air flowing through the body in the direction indicated by the arrow.
4. Install the same pipe-size unit as the pipeline in use. Avoid using fittings, couplings, etc., that restrict the airflow or
baffle the oil out of the air at the lubricator outlet.
5. The lubricator may be filled under pressure by slowly removing the fill plug and pouring oil into the bowl through
the fill tube. The tank may be taken off after the fill plug is removed. Do not replace the fill plug until the tank is
secured in place. NOTE: As the fill plug is removed, the air pressure in the tank will be released.
6. Use only clean non-detergent oil. SAE 10 or lighter is usually best.
7. The rate of oil delivery can be controlled counterclockwise for more and clockwise for less delivery. This lubricator
delivers all of the oil downstream that passes through the sight dome. The oil delivery rate will change
automatically to deliver more oil during higher air flows and less oil for air flows lower than that at which the
original setting was made.
8. Maximum pressure and temperature ratings for metal tanks are 200 PSI (14 Bar) and 175
o
F (79
o
C).
MAINTENANCE
1. Given clean operating conditions, this unit should be trouble-free. Contaminants from dirty oil may collect on the
siphon tube inlet filter, requiring the filter to be cleaned by tapping on a hard surface and blowing off with an air
blow gun. Drain off any contaminants which collect in the bottom of the bowl.
2. IF THE OIL DELIVERY RATE DROPS, shut off the air supply to the lubricator and reduce the pressure in the unit
to zero. Remove the Flow-Guide® variable orifice screw and clean its air passage with a small wire. Check the
bore that the screw fits into for contaminants and clean, if necessary. Be sure that the passageway from the sight
dome cavity into the Flow-Guide® variable orifice post is open. Remove the adjusting screw and clean the needle
and the seat in the body. Inspect and clean the passage from the needle seat down into the adaptor.
3. Drain off any contaminants which collect in the bottom of the bowl.
4. Lubricate o-rings with Parker O-Lube before assembly.
5. Clean plastic bowl with a clean, dry cloth only.
0A3843-00021 Rebuild Kit (Includes all parts except tank, body and sight gauge kit)
003843-00004 Sight Gauge kit for 003843-00001 (not included in 0A3843-00021)
003843-00005 Sight Dome Kit (included in 0A3843-00021)