EasyManua.ls Logo

Minolta EP1030 - Service Mode: Registration and Erase Adjustments; Full Size Registration Adjustment; Enlargement Registration Adjustment; Reduction Registration Adjustment

Minolta EP1030
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjust
Mode
[Service
Mode
p>
Adjust
Mode]
Setting
(The
default
Is
)
<Full
size
registration
adjustment
Corrects
registration
between
the
leading
edge
of
the
original
and
that
of
the
image
in
the
full
size
made
by
varying
the
Synchronizing
Rotter
start
timing.
0.6mm
....
sees
6
+6.0mm
Description
(Smalier
(Greater
deviation)
deviation)
<Entargement
registration
adjustment>
Corrects
registration
between
the
leading
edge
of
the
original
and
that
of
the
Image
in
an
enlargement
made
by
varying
the
Synchronizing
Roller
start
timing.
:
-2.0mm
....
teas
+2.0mm
Description
(Smaller
(Greater
deviation)
deviation)
<Reduction
registration
adjustment>
Corrects
registration
between
the
leading
edge
of
the
original
and
that
of
the
image
in
a
reduction
made
by
varying
the
Synchronizing
Roller
start
timing.
2.0mm
....
sees
-42,0mM
Description
(Smaller
(Greater
deviation)
deviation)
<SDH
registration
adjustment>
Corrects
registration
between
the
leading
edge
of
the
original
fed
via
the
SDH
and
that
of
the
image
by
varying
the
SDH
Registration
Roller
start
timing.
-10mm
....
sees
10mm
Description
(Smaller
(Greater
deviation)
deviation)
S-14
[Service
Mode
>
Adjust
Mode]
Setting
(The
default
Is
)
<Leading
edge
erase
width
adjustment>
Corrects
the
leading
edge
erase
width
by
varying
the
Imag
Erae
Lamp
ON
Adjust
Mode
|
-11.0mm....
+Omm~—....
=+4.0
mm
(Smaller
(Greater
width)
width)
Description
<ATDC
Sensor
adjustment
data>
Manually
enter
the
setting
value
previously
recorded
when
the
starter
has
been
changed
or
the
setting
value
data
automatically
set
by
an
F8
operation
is
cleared.
:
NOTE
For
details,
see
DIS/REASSEMBLY,
ADJUSTMENT.
<Max.
Exposure
Lamp
voltage
adjustment
data>
Manually
enter
the
setting
value
previously
recorded
if
the
max.
Exposure
Lamp
voltage
adjustment
data
set
by
an
F3
operation
Is
cleared
with
Data
Clear
of
Tech.
Rep.
Choice.
NOTE
For
details,
see
DIS/REASSEMBLY,
ADJUSTMENT.
S-15

Other manuals for Minolta EP1030

Related product manuals