T169SBS050404A
4.
Test
©
This
function
allows
the
Tech.
Rep.
to
perform
various
functional
test
and
adjustment.
<Setting
Procedure>
1.
Select
the
Test
function.
(“F1”
appears
on
the
Display
Panel.)
,
2.
Select
the
subfunction
to
be
adjusted
or
checked
using
the
Copy
Quantity
and
Zoom
Key
@
and
press
the
Start
Key.
<Leaving
the
Function>
®
Select
the
next
Test
subfunction
using
the
Copy
Quantity
and
Zoom
Key
©
or
press
the
Clear/Stop
Key
to
quit
the
Test
function.
[Service
Mode
>
Test]
<Paper
Passage
Test>
.
This
test
moves
the
paper
through
the
copier
for
correct
passage.
<Procedure>
1.
Press
the
Start
Key
to
start
the
sequence.
2.
Press
the
Clear/Stop
Key
to
stop
the
sequence.
<Corona
output>
Do
not
use
this
test
as
it
is
only
for
factory
adjustment.
<Exposure
Lamp
Voltage
Adjustment>
This
test
allows
the
Tach.
Rep.
to
adjust
the
maximum
Exposure
Lamp
voltage
and
the
optimum
exposure
setting
in
the
Manual
Exposure
mode.
(It
runs
for
30
sec.)
NOTE
For
details,
see
DIS/REASSEMBLY,
ADJUSTMENT.
|
<AE
Sensor
Automatic
Adjustment>
This
test
automatically
adjusts
the
AE
sensor.
(It
runs
for
5
sec.)
NOTE
|
For
details,
see
DIS/REASSEMBLY,
ADJUSTMENT.
|
<ATDC
Sensor
Automatic
Adjustment>
This
test
automatically
adjusts
the
ATDC
sensor.
S-16
e
Test
Operation
Component
Main
Drive
Motor
PC
Drum
Charge
Edge
Erase
Lamp
[Service
Mode
>
Test]
~
Components
Energized
in
the
Test
S-17
©:
Energized
:
Remain
deenergized