2-6.
PC
DRUM
CHARGE
CORONA
AND
IMAGE
TRANSFER/
PAPER
SEPARATOR
CORONAS
(1)
Removal
of
the
PC
Drum
Charge
Corona
1.
Remove
the
two
Covers.
2.
Remove
the
Ground-Shielded
Harness
Connector.
3.
Remove
the
Drum
Charge
Corona.
1159D091AB
(2)
Cleaning
of
the
Main
Eraser
1.
Using
a
soft
cloth
dampened
with
alcohol,
clean
the
Main
Eraser
by
gently
wiping
its
surface
in
one
direction.
1.
Press
the
Mesh
Holder
on
the
front
of
the
Corona
Unit
in
the
direction
of
arrow
to
remove
the
Grid
Mesh.
1159D172AB
2.
Remove
the
End
Cups
from
the
front
and
rear
end
of
the
Unit.
1159D173AB
D-28
3.
Remove
the
Comb
Electrode,
Drum
charge
Corona.
NOTE
Use
care
not
to
deform
the
Electrode.
When
removing
it,
first
snap
off
Its
spring
end.
1.
Use
a
blower
brush
to
clean
the
Comb
Electrode,
Drum
charge
Corona,
NOTE
if
the
blower
brush
is
not
effective
in
cleaning
the
Comb
Electrode,
Drum
Charge
Corona
use.a
soft
cloth
damp-
ened
with
alcohol
to
clean
serious
contamination.
1.
Blow
all
foreign
matter
off
the
Grid
Mesh
a
blower
brush.
NOTE
ifthe
blower
brush
is
not
effective
in
cleaning
the
Grid,
use
a
soft
cloth
dampened
with
alcohol
to
clean
serious
con-
tamination.
1.
Swing
down
the
Front
Door.
2.
Release
and
swing
up
the
Upper
Half
of
the
copier.
3.
Pull
out
the
Image
Transfer/Paper
Separator
Coronas.
1.
Remove
the
Image
Transfer/Paper
Separator
Corona
Housing.
1159D178AA
D-29