(5)
Adjustment
of
the
Aperture
Blades
@
Requirement
©
There
should
be
no
dark
or
light
bands
running
in
the
feeding
direction
on
copies
produced.
(Adjust
to
obtain
the
mean
irnage
density
for
all
areas.)
@
Important
ef
dark
and
light
bands
running
in
the
feeding
direction
occur
on
copies,
make
this
adjustment
after
checking
following.
1)
The
surfaces
of
the
Mirror
and
Lens
are
free
of
dirt.
2)
The
surfaces
of
the
Exposure
Lamp
and
Main
Erase
Lamp
free
of
scratches
and
dirt.
1.
Make
copies
in
the
following
modes.
Original
+
A4
or
8-1/2”
x
14”
Paper
:
A4
or
8-1/2"
x
14”
Magnification
ratio
:
100
%
Exposure
:Manual
.
(setting
convenient
for
check)
2.
Remove
the
Original
Glass.
3.
Turn
the
copy
on
the
Copy
Tray
Around
as
shown
to
re-
verse
the
leading
and
trailing
edges
and
align
it
with
the
Aperture
Blades.
4.
Adjustto
obtain
the
mean
image
density
for
all
areas
of
the
oopy,
NOTE
To
make
the
image
darker,
move
the
Aperture
Blade
to-
ward
the
Auxiliary
Reflector.
To
make
the
lighter
darker,
move
the
Aperture
Blade
away
from
the
Auxiliary
Reflector.
1159D138AA
D-48
(6)
Adjustment
of
Zoom
Ratio
in
the
Crosswise
Direction
(EP1031/EP1031F
Only)
@
Requirement
©
This
adjustment
is
made
for
the
Zoom
ratio
in
the
crosswise
direction.
A
scale
is
placed
on
the
Original
Glass
to
run
parallel
with
the
scanner
and
the
length
of
the
scale
on
the
copy
is
compared
with
that
of
the
actual
scale.
The
adjustment
must
be
made
so
that
the
difference
between
the
two
dimensions
falls
within
the
following
specifications.
The
difference
should
be
within
+
0.5
%
of
the
actual
length.
Against
200mm,
allowance
is
200
mm
x
0.005
=
1.0
mm
Zoom
Ratio
Specifications
Adjusting
Mode
Satting
Range
Full
size
(x
1.000)
|
220
1.0mm
|
AdiustAt=Lens
Full
33
to
67
ry
Important
This
adjustment
must
be
made
before
the
“Reference
Position
Adjustment”.
1.
Place
a
scale
in
parallel
with
the
Original
Width Scais
and
make
a
copy.
*
Make
a
one
copy
using
Ad
or
8-1/2”
x
14”
paper
at
a
1:1
zoom
ratio.
“tf
the
scale
is
of
plastic
and
transparent,
place
a
blank
sheet
of
paper
on
it.
1159D138AA
2.
Measure
the
crosswise
zoom
ratio
of
the
sample
copy.
Measure
the
length
of
the
scale
on
the
copy
with
the
actual
scale
to
determine
if
there
is
any
deviation.
*
Ifthe
zoom
ratio
deviates
from
the
specifications,
go
to
the
next
stap.