FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 MECHANICAL/ELECTRICAL
98.04.24
M-7
1174SBM0400A
Numbers given in rectangles in the following flowchart are timer values in seconds.
4 SEQUENTIAL EXPLANATION
A The power cord is plugged into the outlet.
ON
AC24V for Drum heating (Transformer)
ON
Drum Dehumidifying
Heater
Paper Dehumidifying
Heater
ON
Only when Dehumidifying
Switch is ON
Power cord is plugged in.
ON
DC5V (Power Supply Unit)
ON
DC24V (Power Supply Unit)
ON
Control panel
ON
The Cooling Fan turns at full speed.
The Cooling Fan turns at half speed.
Fusing Heater Lamp
ON
ON
Scanner Reference Position Sensor
If the Scanner is not at the home position, Scanner Motor is
energized to move the Scanner to the home position.
Lens Reference Position Sensor
If the Lens is not at the home position, Lens Motor is
energized to move the Lens to the home position.
ON
Mirror Reference Position Sensor
If the 4th Mirror is not at the home position, Mirror
Motor is energized to move the Mirror to the home
position.
ON
Starter setup and ATDC Sensor automatic adjustment
Only when the Imaging Unit is new. I/U Fuse blows when the
starter setup sequence is completed normally.
ON
Approx. 3
Approx. 1
B Power Switch is turned ON.