FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 MECHANICAL/ELECTRICAL
98.04.24
M-29
1174SBM1003A
•
The number and location of the Original Size Detecting Sensors vary depending on the
marketing area as shown below.
❍
: Standard
●
: Optional
NOTE
If the optional sensors are installed, set Jumper Connector JP2 on the Original Size Detect-
ing Board as illustrated below and run the F7 operation.
10-3. Sensor Locations
Sensors
CD1
(PC114)
CD2
(PC116)
FD2
(PC113)
FD3
(PC115)
Areas
Metric Areas
❍●❍●
Inch Areas
❍●❍●
Mixed inch/metric Areas
❍❍❍❍
U.S.A and Canada Areas
●●●●
Width (Metric)
Length (Inch)
Letter C
Letter L
FLS
Width (Inch)
Legal
FD2 FD3
11”
×
17”
A5L
B5L
A4L
B4L, B5C
A3L, A4C
CD2
CD1
Length (Metric)
B5C A4C,
A5L
B5L A4L B4L A3L
Invoice
Legal,
Letter L
Letter C,
11”
×
17”
L: Lengthwise
C: Crosswise
Original Size Detecting Board UN2
LED1 LED2
CN1
JP1
JP2
CN2
CN3
CN4
1174M012AB
Position
of JP2
CD2 and FD3
are mounted
CD2 and FD3
are not mounted