Mircom TAS-2000 Series - Auto Programming Function

Mircom TAS-2000 Series
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 57
For the back lobby of Building #1, the set up will be:
NSL ID Speech Path (SP) NSL ID Speech Path (SP)
or Audio Line or Audio Line
NSLA ID 06 04 NSLE ID 99 99
NSLB ID 99 99 NSLF ID 99 99
NSLC ID 99 99 NSLG ID 99 99
NSLD ID 99 99 NSLH ID 99 99
The set up for the back lobby of Building #2:
NSL ID Speech Path (SP) NSL ID Speech Path (SP)
or Audio Line or Audio Line
NSLA ID 07 04 NSLE ID 99 99
NSLB ID 99 99 NSLF ID 99 99
NSLC ID 99 99 NSLG ID 99 99
NSLD ID 99 99 NSLH ID 99 99
SETTING THE ELEVATOR ID AND TIMER
Each controller must have a unique ID.
Set the Dip Switch SW2 on the elevator controller board. See below for
switch function:
Dip Switch # Function
1-5 Used for setting the controller ID (address)
1st switch is the least significant bit and the 5
th
switch is the most significant bit.
6,7 spare/not used
8 Baud rate select. 2400 (switch to the left/off) or 9600 (switch to the right/on)
Note: Make sure to match all controller’s baud rates.
The Elevator Restriction cabinet can house up to eight (8) 2012 Relay Modules or up to ninety-six (96) Form C type
relay contacts. These relay contacts are normally connected to the input circuits of the elevator manufacturer’s
Button Controller. When a resident releases the door, a designated relay is energized to signal the elevator button
controller to enable a particular floor select button on the elevator while others are disabled. In effect, the
elevator will be restricted to stop only on the selected floor. The time period for these relays to remain in an
energized state depends on the timer period assigned. Please note that each Elevator Restriction cabinet can have
only one common timer. The timer decimal value is a multiple of 15 seconds. For example: Entering 03 would
mean the relay will remain ON for 45 seconds.
Record the Elev. ID and Timer values below for future reference.
Elev. ID Timer Period Elev. ID Timer Period
ELEV-A ID _ _ _ _ ELEV-E ID _ _ _ _
ELEV-B ID _ _ _ _ ELEV-F ID _ _ _ _
ELEV-C ID _ _ _ _ ELEV-G ID _ _ _ _
ELEV-D ID _ _ _ _ ELEV-H ID _ _ _ _
NOTE: Press # or enter 99 for any entries not used rather than leave blank.