OPERATING MANUAL
MBD-2 (IM-278/U)
Personal Dosimeter
Document # 15-00167
Revision 1
December 2018

Table of Contents

Questions and Answers

  • J
    jonesmariaSep 12, 2025
    What to do when Mirion Technologies Measuring Instruments detect REG_UP I/O line signal too early?
    • N
      Nicholas WilliamsSep 12, 2025
      If your Mirion Technologies Measuring Instruments device detects the REG_UP I/O line signal too early due to a failure in the voltage block regulator, restart the device by removing and re-inserting the battery. If the error message repeats, remove the device from service.
  • S
    Shannon ReynoldsSep 12, 2025
    What to do if Mirion Technologies MBD-2 Measuring Instruments reading fails due to corruption of result memory?
    • B
      buckleyvictoriaSep 12, 2025
      If the measurement result reading fails on your Mirion Technologies Measuring Instruments device due to corruption of the result memory, restart the device by removing and re-inserting the battery. If the error message repeats, remove the device from service.
  • Y
    Yolanda GomezSep 9, 2025
    What to do if Mirion Technologies Measuring Instruments cannot determine reading result position?
    • H
      Heidi PowellSep 10, 2025
      If your Mirion Technologies Measuring Instruments device cannot determine the reading result position in flash memory due to a failure in flash memory access or corruption of memory contents, restart the device by removing and re-inserting the battery. If the error message repeats, remove the device from service.
  • T
    Taylor ThomasSep 8, 2025
    What to do if Mirion Technologies MBD-2 report invalid type during memory scan?
    • W
      williamsjessicaSep 8, 2025
      If your Mirion Technologies Measuring Instruments device reports an invalid type during a memory scan, indicating a failure or corruption in flash memory, restart the device by removing and re-inserting the battery. If the error message repeats, remove the device from service.
  • J
    James WallaceSep 7, 2025
    What does it mean if my Mirion Technologies MBD-2 Measuring Instruments device displays 'dbAt' with dose value?
    • N
      nicholassanchezSep 7, 2025
      If your Mirion Technologies Measuring Instruments device displays a 'dbAt' message alternating with the dose value, it means the dose battery (internal detector batteries) is reporting less than 25% above the voltage low limit (5500). No action is required unless the message changes. Alternatively, you can replace the internal dose batteries (3) with model CR1025.
  • H
    Holly WilliamsAug 23, 2025
    What to do if Mirion Technologies Measuring Instruments show 'PbAt' permanently?
    • P
      phillip39Aug 23, 2025
      If the 'PbAt' message is permanently displayed on your Mirion Technologies Measuring Instruments device, it means the battery is exhausted. Replace it with a new CR2450 battery.
  • R
    Robert ReynoldsSep 5, 2025
    What does it mean if Mirion Technologies Measuring Instruments show indication of an intentional hard reset?
    • S
      Sandra WilsonSep 6, 2025
      If your Mirion Technologies Measuring Instruments device shows an indication of an intentional hard reset due to corruption of a parameter, data structure, or other elements, it is an informational message, and no action is required.
  • C
    Courtney GrahamSep 4, 2025
    What to do if Mirion Technologies MBD-2 Measuring Instruments give error after battery replacement?
    • R
      Ryan WeaverSep 4, 2025
      When the battery is replaced and your Mirion Technologies Measuring Instruments device performs an intentional hard reset, it's an informational message, and the error message should disappear after the reset. If the error message repeats, remove the device from service.
  • T
    Tony RojasSep 3, 2025
    What to do if Mirion Technologies MBD-2 Measuring Instruments show low battery voltage?
    • N
      nancymarshallSep 3, 2025
      If your Mirion Technologies Measuring Instruments device shows a low main battery voltage (less than 2200 mV) with no battery icon and a permanent 'PbAt' message, replace the main battery with model CR2450.
  • R
    Robert BoothSep 2, 2025
    What does it mean if Mirion Technologies MBD-2 display corrupt segments?
    • K
      kelly45Sep 2, 2025
      If your Mirion Technologies Measuring Instruments device displays corrupt or erratic segments, physical damage may have occurred to the LCD. If there is no visual damage, there might be corruption to the histogram data. If the problem repeats without visual LCD damage, remove the device from service.