Chapter 7 Peripheral Devices
7-5
7-3-2 Selection from input current
Use the following table to select the contactors so the total input current for each unit does not exceed
the rated continuity current.
Input current table
SVJ2 total output capacity
1.5kW or less 3.5kW or less 7kW or less 10kW or less 13kW or less 16kW or less
Input current
10A 20A 30A 40A 50A 60A
MDS-B-SPJ2
MDS-B-SPJ2-02
MDS-B-SPJ2-04
MDS-B-SPJ2-075
MDS-B-SPJ2-15
MDS-B-SPJ2-22
MDS-B-SPJ2-37
MDS-B-SPJ2-55 MDS-B-SPJ2-75 MDS-B-SPJ2-110
Input current
10A 20A 30A 40A 50A
Converter unit
MDS-A-CR-10
MDS-A-CR-15
MDS-C1-CV-37
MDS-A-CR-22
MDS-A-CR-37
MDS-C1-CV-55
MDS-A-CR-55
MDS-C1-CV-75
MDS-A-CR-75
MDS-A-CR-90
MDS-C1-CV-110
Input current
10A 20A 30A 40A 50A
Contactor selection table 2
Contactor rated continuity
current
(Total input current)
20A 32A 50A 60A
Recommended contactor
(Mitsubishi Electric Corp.:
Option part)
S-N10
AC200V
S-N20
AC200V
S-N25
AC200V
S-N35
AC200V
The contactor is selected for the MDS-B-SVJ2-10 with 4 HC102 axes and an MDS-C1-CV-55
connected.
< Selection from rush current >
(SVJ2-10 × 4 axes rush current) + (MDS-C1-CV-55 rush current) = 4 × 100A + 15A
= 415A
Therefore, S-K50 200VAC.
< Selection from input current >
(HC102 × 4 axes input current) + (MDS-C1-CV-55 input current) = 30A + 30A = 60A
Therefore, S-N35 200VAC.
From these, the S-K50 200VAC is selected as having the larger of the two capacities.