Chapter 3 Installation
3-2
3-1 Installation of servo amplifier
3-1-1 Environmental conditions
Environment Conditions
Ambient temperature
0°C to +55°C (with no freezing)
Ambient humidity 90% RH or less (with no dew condensation)
Storage temperature
–20°C to +65°C (with no freezing)
Storage humidity 90% RH or less (with no dew condensation)
Atmosphere Indoors (Where unit is not subject to direct sunlight)
Must be no conductive fine particles, corrosive gas,
flammable gas, oil mist or dust.
Altitude 1000m or less above sea level
Vibration 5.9m/sec
2
(0.6G) or less
CAUTION
1. Install the unit on noncombustible material. Direct installation on
combustible material or near combustible materials could lead to fires.
2. Follow this Instruction Manual and install the unit in a place where the weight
can be borne.
3. Do not get on top of or place heavy objects on the unit.
Failure to observe this could lead to injuries.
4. Always use the unit within the designated environment conditions.
5. Do not let conductive objects such as screws or metal chips, etc., or
combustible materials such as oil enter the servo amplifier or servomotor.
6. Do not block the servo amplifier intake and outtake ports. Doing so could
lead to failure.
7. The servo amplifier and servomotor are precision devices, so do not drop
them or apply strong impacts to them.
8. Do not install or run a servo amplifier or servomotor that is damaged or
missing parts.
9. When storing for a long time, please contact your dealer.
CAUTION
1. Always observe the installation directions. Failure to observe this could lead to
faults.
2. Secure the specified distance between the servo amplifier and control
panel, or between the servo amplifier and other devices. Failure to observe
this could lead to faults.