Loading...
Chapter 2 Wiring and Connection
2-6
2-2-3 How to use the control circuit terminal block (MDS-B-SVJ2-01~07)
(1) For connector of the spring lock type
Treatment of wire end
(a) Single strand
Peel the wire sheath, and use the wire.
Sheeth
Core
A
pprox. 10mm
(b) Stranded wire
1) When the wire is inserted directly
Peel the wire sheath, and then twist the core wires. Take care to prevent short circuits with
the neighboring poles due to the fine strands of the core wires. Solder plating onto the core
wire section could cause a contact defect and must be avoided.
2) When the twisted wires are put together using a bar terminal
Use the bar terminal shown below.
Wire size Bar terminal type
[mm
2
] AWG For one wire For two wires
Crimping tool Manufacturer
1.25/1.5 16 AI1.5-10BK AI-TWIN2×1.5-10BK
2/2.5 14 AI2.5-10BU
CRIMPFOX ZA 3 Phoenix contact
Cut the wire running out of bar terminal to less than 0.5 mm
Less than 0.5mm
When using a bar terminal for two wires, insert the wires in the direction where the
insulation sleeve does not interfere with next pole, and pressure them.
Pressur
e
Pressur
e

Table of Contents