10. Troubleshooting 
 
 
 
   
10 - 5
 
No.  Alarm name  Alarm details  Stopping method Reset 
50  Overload 1  Overload detection level became over 100%.  The motor or the 
drive unit is overloaded. 
Deceleration control
NR 
51  Overload 2  Current command of more than 95% of the unit's max. current 
was being continuously given for longer than 1 second. 
Dynamic brakes 
NR 
52  Excessive error 1  A difference between the actual and theoretical motor positions 
during servo ON exceeded the setting value.  
Dynamic brakes 
NR 
53  Excessive error 2  A difference between the actual and theoretical motor positions 
during servo OFF exceeded the setting value. 
Dynamic brakes 
NR 
55  External emergency stop error  There is no contactor shutoff command, even after 30 seconds 
has passed since the external emergency stop was input. 
Dynamic brakes 
NR 
5F  External contactor error  A contact of the external contactor is welding.  Or the contactor 
fails to be ON during ready ON. 
Deceleration control
NR 
88  Watchdog  The system does not operate correctly.  Dynamic brakes 
AR 
 
 
• Stopping method Deceleration control : The motor stops with the deceleration control time 
constants set with the parameters (SV056). 
  Dynamic brakes  : The dynamic brakes activate simultaneously with the 
alarm occurrence to stop the motor. 
    Initial error  : This alarm is detected before ready ON. 
 
•  Resetting method  NR  : The alarm can be reset with the NC reset button. The alarm can also be 
reset with the PR and AR resetting conditions. 
    PR  : The alarm can be reset by turning the NC power OFF and ON. The alarm 
can also be reset with the AR resetting conditions. 
If the control axis is removed, the alarm can be reset with the NC reset 
button. (Excluding alarms 32 and 37.) 
    AR  : The alarm can be reset by turning the servo drive unit's power OFF and 
ON.