1 SYSTEM CONFIGURATION
1.2 System Configuration Specifications
47
1
*1 When the CC-Link IE Controller Network function of the RJ71EN71 is used, there are restrictions on the firmware versions of the
RnCPU, the C Controller module, and the RJ71EN71. ( Manual for each module)
*2 These modules occupy two slots. When these modules are used with the RnCPU or the C Controller module, there are restrictions on
each firmware version. ( User's Manual (Application) for the CPU module used)
*3 When the RJ71EN71 is used with a remote head module, there are restrictions on network combinations. ( MELSEC iQ-R Ethernet/
CC-Link IE User's Manual (Startup))
*4 When a redundant system is built with a master station of CC-Link IE Field Network, these modules cannot be used with a remote head
module.
*5 When a redundant system is built with these modules, there are restrictions on the firmware version. ( Manual for each module)
*6 Depending on the CPU module used, there are restrictions on the firmware version of the MES interface module. ( MELSEC iQ-R
MES Interface Module User's Manual (Application))
*7 The method for enabling parameters differs depending on the firmware version of the C Controller module. ( MELSEC iQ-R C
Controller Module User's Manual (Startup))
*8 "Target" cannot be set to "RPDO" and "TPDO" under "Refresh Setting" in "Module Parameter". Parameter error (error code: 2220H)
occurs.
*9 Use the RnCPU with firmware version "28" or later, the RnENCPU with firmware version "17" or later, and the RnPCPU with firmware
version "12" or later. When the CPU module with these firmware versions or earlier is used, there is the restriction on *8.
Blank cover module
MELSEC-Q series
The following table lists the MELSEC-Q series modules and extension cables which can be used in the MELSEC iQ-R series
system.
When a MELSEC-Q series module is used, refer to the following.
Page 158 How to Use MELSEC-Q Series Modules
CC-Link IE Field Network RJ71GF11-T2
*5
 
RJ71EN71  
CC-Link
*5
RJ61BT11  
Serial communication
*5
RJ71C24, RJ71C24-R2, RJ71C24-
R4
 
AnyWireASLINK master module RJ51AW12AL  
BACnet module RJ71BAC96  
CANopen module RJ71CN91
*9
*9
*9

*8

Item Model Rn Rn
EN
RnP
(P)
RnP
(R)
Rn
MT
Rn
NC
Rn
C
Rn
SF
Rem Rem
(R)
Blank cover module RG60  
Item Model
Base unit Extension base unit Q52B, Q55B, Q63B, Q65B, Q68B, Q612B
Q series large type extension base unit
*5
Q55BL, Q65BL, Q68BL
Q series large type extension base unit (AnS series size)
*5
Q55BLS, Q65BLS, Q68BLS, Q55BLS-D, Q65BLS-D, Q68BLS-D
Extension cable QC05B, QC06B, QC12B, QC30B, QC50B, QC100B
Power supply module Q61P, Q61P-A1, Q61P-A2, Q62P, Q63P, Q64P, Q64PN, Q61P-D
Item Model Rn Rn
EN
RnP
(P)
RnP
(R)
Rn
MT
Rn
NC
Rn
C
Rn
SF
Rem Rem
(R)