2 - 30
2. DETAILS OF MIGRATION FROM Q17nCPUN(-T) TO RnMTCPU
2.4.2 List of divertible/not divertible data (SV13/SV22)
Q17nCPUN(-T) data name Divertible/not divertible Remarks
System settings
Basic settings
Base setting △
(Note-1)
Multiple CPU setting △
(Note-1), (Note-2)
System basic setting ○
SSCNET setting △
(Note-3)
System configuration △
(Note-1)
SSCNET configuration ○ (Note-4)
High-speed read data ○
Servo data settings
Servo data ○ (Note-5)
Servo parameter ○ (Note-6)
Parameter block ○
Limit output data ○
Motion SFC programs
Motion SFC parameter ○
Motion SFC program ○ (Note-7)
Servo programs
K mode allocation ○ SV22 only
Servo program ○
Mechanical system program ○ SV22 only (Note-8)
Cam data (converted data) ○ SV22 only (Note-8)
Device memory ○
Backup data ×
Communication setting ×
○
: Divertible,
△
: Partially divertible,
×
: Not divertible
(Note-1): MELSOFT MT Developer2 reads parameters set in MELSOFT GX Works3.
Therefore, the existing data which have been set in MELSOFT MT Developer2 for
Q17nCPUN(-T) cannot be diverted.
(Note-2): When the system parameters have been set already, only the auto refresh settings for
Q17nCPUN(-T) can be diverted ([R Series Common Parameter] - [Multiple CPU Setting] -
[Refresh (END) Setting])
(Note-3): Select SSCNETIII or SSCNETIII/H at SSCNET setting.
(Note-4): The servo amplifiers are replaced with MR-J4-B.
(Note-5): Review the fixed parameters according to the resolution per servo motor revolution.
(Number of pulses per revolution and movement amount per revolution)
(Note-6): Refer to “MELSOFT MT Developer2 Help” for conversion rules for servo parameters.
(Note-7): When Motion registers (Monitor devices) are used in the program, they need to be changed.
(Note-8): Refer to section 2.4.4 for replacement of mechanical system programs and cam data.