504
APPENDICES APPENDIX
Appendix 3 Buffer Memory
516
(204H)
For confirmation
of user frame
Number of registered user frames
0: No registration 1 to 200: Number of
registered frames
Depend
s on
registrat
ion
status.
R 
517 to 541
(205H to 21DH)
User frame registration status (for registration
number check)
0: No registration 1: Registered
Bit corresponding to registration No. is 0(OFF)/
1(ON).
Registration No. 3E8H (1000): Address 205H
(b0) to Registration No. 4AFH(1199): Address
211H (b7)
Depend
s on
registrat
ion
status.
542
(21EH)
For confirmation
of user frame
Number of registered default registration
frames (for system)
Depend
s on
registrat
ion
status.
Page 258 Default
registration frame
(read only)
543, 544
(21FH, 220H)
Use prohibited System area
545
(221H)
For confirmation
of the modem
function
Modern function error code
(error code when the modem function is being
used)
0 : Normal completion
Other than 0 (error code) : Abnormal
completion
0RW Page 161 Buffer
memory
546
(222H)
Modem function sequence status
0: Idle
1: Waiting for initialization
2: Initializing modem
3: Waiting
4: Checking password
5: Communicating
7: Modem disconnected
0R
547
(223H)
Number of data registration for connection
0: No registration 1 to 30: Number of
registrations
Depend
s on
registrat
ion
status.
548, 549
(224H, 225H)
Data registration status for connection (for
confirmation of registration No.)
0: No registration 1: Registered
Bit corresponding to registration No. is 0(OFF)/
1(ON).
Registration No. BB8H (3000) : Address 224H
(b0) to Registration No. BD5H (3029) : Address
225H (b13)
Depend
s on
registrat
ion
status.
550
(226H)
Number of data registration for initialization
0: No registration 1 to 30: Number of
registrations
Depend
s on
registrat
ion
status.
551, 552
(227H, 228H)
For confirmation
of the modem
function
Data registration status for initialization (for
confirmation of registration No.)
0: No registration 1: Registered
Bit
corresponding to registration No. is 0(OFF)/
1(ON).
Registration No.9C4H (2500) : Address 227H
(b0) to Registration No. 9E1H (2529) : Address
228H (b13)
Depend
s on
registrat
ion
status.
R
553 to 589
(229H to 24DH)
Use prohibited System area
Address
Dec (Hex)
Purpose Name Defaul
t value
Protocol Reference
CH1 CH2 MC Non Bi Pd