Mitsubishi AE-200E - User Manual

Mitsubishi AE-200E
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Contents
1. Safety precautions ..............................................................5
2. Introduction .........................................................................7
3. Parts to be used ................................................................13
4. Preparation .......................................................................15
5. Settings on the LCD ..........................................................31
6. Settings using Initial Setting Tool ......................................90
7. Settings using Web Browser for Initial Settings ..............136
8. Maintenance ...................................................................183
9. Troubleshooting ..............................................................188
10. Advance preparation .......................................................194
11. Explanation of terms .......................................................205
Appendix 1: Air-conditioner ON/OFF trial run .......................210
Appendix 2: Added functions ................................................214
Air Conditioning Control System
Centralized Controller
AE-200A/AE-50A/EW-50A
AE-200E/AE-50E/EW-50E
Before using the controller, please read this Instruction Book carefully to ensure proper operation.
Retain this manual for future reference.
WT07627X03
Instruction Book
–Initial Settings–
<ORIGINAL>

Table of Contents

Questions and Answers

  • L
    Lisa LambertAug 17, 2025
    What to do if an error occurs when updating Mitsubishi AE-200E centralized controllers?
    • C
      Christopher MorrisAug 17, 2025
      If an error occurs during the update of your Mitsubishi Control Systems centralized controllers, there are a couple of things to check. First, verify that the LAN connection between the PC running the Update Tool and the controller is stable. Second, double-check that you've entered the correct ID and password for the controller in the authentication information screen. If the issue persists, ensure there are no communication failures.
  • C
    Catherine SalasAug 20, 2025
    What to do if the message 'Update failed' appears in the Status column of Mitsubishi Control Systems?
    • P
      paul51Aug 20, 2025
      If you see an 'Update failed' message in the Status column, it could be due to a couple of reasons. First, check the LAN connection between the PC and the centralized controller to ensure it hasn't been interrupted during the update. Communication failures may also cause this issue. After checking the connection, click [Acquire data] on the main screen to verify if the version of the centralized controller has been updated. If not, try the update again.
  • A
    Ashley EvansAug 23, 2025
    What to do if an error occurs when acquiring centralized controller data in Mitsubishi AE-200E?
    • B
      belindagallagherAug 23, 2025
      If you encounter an error when acquiring centralized controller data, first ensure that the IP address of the centralized controller matches the one entered in the main screen. If they are different, enter the correct IP address. Also, verify that the LAN connection between the PC with the Update Tool installed and the centralized controller is properly established.
  • L
    Lori McconnellAug 26, 2025
    What to do if an error occurs when I click [Update] on the main screen of Mitsubishi AE-200E Control Systems?
    • L
      loweronaldAug 26, 2025
      If you encounter an error when clicking [Update] on the main screen, it may be because the data acquisition of all centralized controllers has not been completed. Check the 'Destination IP address' and 'Status' columns to identify any controllers whose data hasn't been acquired. Then, click [Acquire data] to complete the process.
  • M
    Matthew BatesAug 28, 2025
    What does it mean if the message 'IP addresses overlap' appears in the Status column of Mitsubishi Control Systems?
    • H
      heidi43Aug 28, 2025
      If the message 'IP addresses overlap' appears, it means that the IP addresses entered in the 'Destination IP address' column of the main screen are overlapping. To resolve this, check the IP address of the indicated centralized controller and re-enter the correct IP address.
  • M
    Michelle HutchinsonAug 31, 2025
    What to do if an error occurs when the update file is selected in Mitsubishi Control Systems?
    • C
      Cindy GarciaAug 31, 2025
      If you get an error when selecting the update file, it might be because you've selected the wrong file. Make sure the file name is in the format “AE200_ FW####_****.dat”, where #### represents the software version. If not, re-select the correct file.
  • E
    Edward GomezSep 2, 2025
    What to do if the versions of the update file for AE-200 and the update file for AE-50/EW-50 do not match in Mitsubishi AE-200E Control Systems?
    • D
      daniel35Sep 3, 2025
      If the versions of the update files for AE-200 and AE-50/EW-50 do not match, you need to verify the versions of both files. Then, re-select the update files to ensure their versions match.
  • B
    Brenda VillarrealSep 5, 2025
    Why does the message 'Invalid IP address' appear in the Status column of Mitsubishi AE-200E?
    • S
      Samantha ReedSep 5, 2025
      If you see the message 'Invalid IP address' in the Status column, it indicates that the IP address was not entered according to the required format. Verify that the IP address is entered correctly, referring to section 3-2 “Inputting IP address of centralized controller” for the specified format.
  • M
    muellerchristinaSep 8, 2025
    What to do if the update file for AE-200 is not selected in Mitsubishi Control Systems?
    • C
      Collin FitzgeraldSep 8, 2025
      If the update file for AE-200 is not selected, click [Browse...] for AE-200 and select the correct update file.
  • A
    Andrew GonzalezSep 12, 2025
    What to do if the update file for AE-50/EW-50 is not selected in Mitsubishi Control Systems?
    • J
      James MorrisSep 12, 2025
      If the update file for AE-50/EW-50 is not selected, click [Browse...] for AE-50/EW-50 and select the correct update file.

Mitsubishi AE-200E Specifications

General IconGeneral
CategoryControl Systems
Input Voltage100-240 VAC
Number of Inputs16
Number of Outputs16
Programming LanguageLadder Logic
Memory Capacity8KB
Communication PortRS-485
Output TypeRelay