4
PARAMETERS
127
Position control by vector control
481
Ninth position feed
amount lower 4 digits
0 0 to 9999
×× 9 Speed (Pr. 233)
482
Ninth position feed
amount upper 4 digits
0 0 to 9999
483
Tenth position feed
amount lower 4 digits
0 0 to 9999
× × 10 speed (Pr. 234)
484
Tenth position feed
amount upper 4 digits
0 0 to 9999
485
Eleventh position feed
amount lower 4 digits
0 0 to 9999
× 11 speed (Pr. 235)
486
Eleventh position feed
amount upper 4 digits
0 0 to 9999
487
Twelfth position feed
amount lower 4 digits
0 0 to 9999
 ××12 speed (Pr. 236)
488
Twelfth position feed
amount upper 4 digits
0 0 to 9999
489
Thirteenth position feed
amount lower 4 digits
0 0 to 9999
 × 13 speed (Pr. 237)
490
Thirteenth position feed
amount upper 4 digits
0 0 to 9999
491
Fourteenth position feed
amount lower 4 digits
0 0 to 9999
 × 14 speed (Pr. 238)
492
Fourteenth position feed
amount upper 4 digits
0 0 to 9999
493
Fifteenth position feed
amount lower 4 digits
0 0 to 9999
15 speed (Pr. 239)
494
Fifteenth position feed
amount upper 4 digits
0 0 to 9999
The above parameters can be set when the FR-A7AP (option) is mounted.
Parameter
Number
Name Initial Value
Setting
Range
Selection Method
(OFF:
×, ON: )
Position feed
frequency
REX RH RM RL