EasyManua.ls Logo

Mitsubishi FR-A740-00023-EC - Wiring and Arrangement of RS-485 Terminals

Mitsubishi FR-A740-00023-EC
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
317
Communication operation and setting
4
PARAMETERS
4.24.2 Wiring and arrangement of RS-485 terminals
(1) RS-485 terminal layout
(2) Connection of RS-485 terminals and wires
Loosen the terminal screw and insert the cable into the terminal.
Name Description
RDA1
(RXD1+)
Inverter receive+
RDB1
(RXD1-)
Inverter receive-
RDA2
(RXD2+)
Inverter receive+
(for branch)
RDB2
(RXD2-)
Inverter receive-
(for branch)
SDA1
(TXD1+)
Inverter send+
SDB1
(TXD1-)
Inverter send-
SDA2
(TXD2+)
Inverter send+
(for branch)
SDB2
(TXD2-)
Inverter send-
(for branch)
P5S
(VCC)
5V
Permissible load current 100mA
SG
(GND)
Earth (Ground)
(connected to terminal SD)
Screw size M2
Wire the stripped cable after twisting it to prevent it from
becoming loose. In addition, do not solder it.
Use a bar terminal as necessary.
Tightening
torque
0.22N•m to 0.25N•m
Cable size
0.3mm
2
to 0.75mm
2
Screwdriver
Small flat-blade screwdriver
(Tip thickness: 0.4mm /tip width: 2.5mm)
CAUTION
Undertightening can cause signal loss or malfunction. Overtightening can cause a short circuit or malfunction due to damage to
the screw or unit.
RXD
RDA1
(RXD1+)
RDB1
(RXD1-)
RDA2
(RXD2+)
RDB2
(RXD2-)
SDA1
(TXD1+)
SDB1
(TXD1-)
SDA2
(TXD2+)
SDB2
(TXD2-)
P5S
(VCC)
SG
(GND)
P5S
(VCC)
SG
(GND)
VCC
TXD
OPEN
100Ω
Terminating resistor switch
Factory-set to "OPEN".
Set only the terminating resistor switch of
the remotest inverter to the "100Ω" position.
5mm
Cable stripping size

Table of Contents

Related product manuals