EasyManua.ls Logo

Mitsubishi FR-A740-00023-EC - Selection of Regenerative Brake and DC Feeding (Pr. 30, Pr. 70)

Mitsubishi FR-A740-00023-EC
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
198
Motor brake and stop operation
4.14.2 Selection of regenerative brake and DC feeding (Pr. 30, Pr. 70)
<01800 or less>
When making frequent starts/stops, use the optional high-duty brake resistor (FR-ABR), brake unit (FR-BU2,
BU, FR-BU, MT-BU) to increase the regenerative brake duty.
Use a power regeneration common converter (FR-CV) or power regeneration converter (MT-RC) for continuous
operation in regenerative status.
Use a high power factor converter (FR-HC, MT-HC) to reduce harmonics, improve the power factor, or
continuously use the regenerative mode.
You can select either DC feeding mode 1 in which operation is performed with DC power (terminal P/+, N/-) or
DC feeding mode 2 in which operation is performed normally with the AC power (terminal R/L1, S/L2, T/L3) and
performed with DC power such as battery at occurrence of power failure.
Parameter
Number
Name
Initial
Value
Setting Range Description
30
Regenerative function
selection
0
Regeneration unit
Terminal for power
supply to the inverter
0
Built-in brake resistor, without
regenerative function, brake
unit (FR-BU2 [other than MT-
BU5 mode]
, FR-BU, BU type)
R/L1, S/L2, T/L3
10
P/+, N/-
(DC feeding mode 1)
20
R/L1, S/L2, T/L3 - P/+, N/-
(DC feeding mode 2)
1
High-duty brake resistor, brake
unit (FR-BU2 [MT-BU5 mode],
MT-BU5), power regeneration
converter (MT-RC)
R/L1, S/L2, T/L3
11
P/+, N/-
(DC feeding mode 1)
21
R/L1, S/L2, T/L3 - P/+, N/-
(DC feeding mode 2)
2
High power factor converter
(FR-HC, MT-HC), power
regeneration common
converter (FR-CV)
P/+, N/-
70
Special regenerative
brake duty
0%
01800 or
less
0 to 30%
Set the %ED of the built-in brake transistor operation.
02160 or
more
0 to 10%
Regeneration Unit
Power Supply to
the Inverter
Pr. 30
Setting
Pr. 70
Setting
Remarks
Built-in brake (00250 or less)
,
brake unit (FR-BU2
, FR-BU, BU)
R/L1, S/L2, T/L3
0
(initial value)
The regenerative brake duty is as follows.
FR-A740-00023 to 00250 . . . 2%
Other than the above . . . . . . 0%
(without built-in brake resistor)
P/+, N/- 10
R/L1, S/L2, T/L3 -
P/+, N/-
20
High-duty brake resistor (FR-ABR)
(00620 or less)
R/L1, S/L2, T/L3 1
10/6%
Change the setting according to the
capacity.
(00250 or less / 00310 or more)
P/+, N/- 11
R/L1, S/L2, T/L3 -
P/+, N/-
21
High power factor converter (FR-HC),
power regeneration common
converter (FR-CV)
P/+, N/- 2
0
(initial value)

Table of Contents

Related product manuals