200
Motor brake and stop operation
(5) DC feeding mode 1 (Pr. 30 = "10, 11")
Setting "10, 11" in Pr. 30 enables DC power supply operation.
Leave the AC power supply connection terminal R/L1, S/L2, and T/L3 open and connect the DC power supply to
terminal P/+ and N/-. Also, remove jumpers across terminal R/L1-R1/L11 and S/L2-S1/L21, and connect terminals
R1/L11 and S1/L21 to terminal P/+ and N/-.
The diagram below is a connection example.
R/L1
S/L2
T/L3
U
V
W
P/+
N/-
IM
STF
STR
R1/L11
S1/L21
10
2
2
3
1
5
(+)
(-)
MC
Inrush
current
limit circuit
DC power
Forward rotation start
Reverse rotation start
Contact input common
Frequency command
Frequency setting
potentiometer
1/2W1kΩ
Earth
(Ground)
Inverter
PC