314
Selection of operation mode and operation location
[Explanation of table]
External : Control is valid only from external terminal signal.
NET : Control only from communication is valid
Combined : Control is valid from either of external terminal and communication.
⎯ : Control is invalid from either of external terminal and communication.
Compensation : Control by signal from external terminal is only valid when Pr. 28 Multi-speed input compensation selection = "1"
(6) Switching of command source by external terminal (X67)
⋅ In network operation mode, the command source switching signal (X67) can be used to switch the operation
command source and speed command source. This signal can be utilized to control the signal input from both the
external terminal and communication.
⋅ Set "67" in any of Pr. 178 to Pr. 189 (input terminal function selection) to assign the X67 signal to the external
terminal.
⋅ When the X67 signal is off, the operation command source and speed command source are external.
Selective function
Pr. 178 to Pr. 189 setting
42 X42
Torque bias selection 1
NET External
43 X43
Torque bias selection 2
NET External
44 X44
P/PI control switchover
NET External
50 SQ
Sequence start
NET External
60 STF
Forward rotation command
NET External
61 STR
Reverse rotation command
NET External
62 RES
Reset
External
63 PTC
PID forward action switchover
External
64 X64
PID forward action switchover
NET External NET External
65 X65
PU-NET operation switchover
External
66 X66
External-NET operation
switchover
External
67 X67
Command source switchover
External
68 NP
Conditional position pulse
train sign
External
69 CLR
Conditional position droop
pulse clear
External
70 X70
DC feeding operation
permission
NET External
71 X71
DC feeding cancel
NET External
74 X74
Magnetic flux decay output
shutoff
NET External
REMARKS
⋅ The control source of communication is as set in Pr. 550 and Pr. 551.
X67 Signal State Operation Command Source Speed Command Source
No signal assignment
According to Pr. 338 According to Pr. 339
ON
OFF Operation is valid only from external terminal signal.
REMARKS
⋅ The ON/OFF state of the X67 signal is reflected only during a stop. It is reflected after a stop when the terminal is switched
during operation.
⋅ When the X67 signal is off, a reset via communication is disabled.
CAUTION
⋅ Changing the terminal assignment using Pr. 178 to Pr. 189 (input terminal function selection) may affect the other functions. Please
make setting after confirming the function of each terminal.
♦ Parameters referred to ♦
Pr. 28 Multi-speed input compensation selection Refer to page 164.
Pr. 59 Remote function selection Refer to page 164.
Pr. 79 Operation mode selection Refer to page 301.
Operation
Location
Selection
Pr. 338 Communication operation command
source
0: NET 1: External
Remarks
Pr. 339 Communication speed command
source
0: NET
1:External 2:External
0: NET
1:External 2:External