4.2 Control circuit
(1) Input signal circuits
darn4 if terminal
10 is connected to
Check the wiring
Frequency reference
(2W 1KQ)
c_( Current input DC4 - 20mA
0
-< Auxiliary input DC 0 - +lOV 1OV
___( Apxiliary input DC0 - f 5 V SV
A B C FM SD 10 2 5 4
1 K 1 E SD STF STR JoG
SE RUN SU IPF OL FU RL RM RH RT AU STOPMRS RES SD
Multi-speed selection
uzl
CS SD
This terminal is available in models larger than FR-Z220-15K
and FR-Z240-11K. Use it for
“restart after instantaneous
power failure”, or for
“commercial power/inverter select “.
0 Restart after instantaneous power failure ****** Short-circuit
between terminals CS and SD.
0 Commercial power/inverter select ***-** Use a circuit which
closes the MC inserted on the inverter output side and
at the same time short-circuit between terminals CS and
SD.
.O
-12-